Showing posts with label digital. Show all posts
Showing posts with label digital. Show all posts

Monday, November 17, 2014

Digital basic logic gates

Digital basic logic gates, or often also called Boelan logic gates is a digital logic gate will output a logic 0 and 1 corresponds to the input received from each gate depends on the function logic. In the digital basic logic, there are 3 basic logic gates, ie AND gates, OR gates, NOT gates. Third this gate produces 4 next digital logic gates, namely: NAND gates, NOR gates, XOR gates, gate XAND.
Digital
AND Logic Gate
AND logic gate has the output formula AB = C, ie when both its inputs are not all the logic 1 output will be logic 0 and when both input logic 1 then the new output is logic 1.

OR Logic Gate
OR logic gate having an output summing function can be formulated A + B = C ie if one input is logic 1 then the output will be logic 1 and when both input logic 0 then the new output will be logic 0.

NOT logic gate
NOT logic gate or often also called inverting logic gates. NOT gate will output a value opposite of the input.
ReadMore..

Sunday, October 26, 2014

Digital control system applications

Digital Control System is a branch of the control system with continuous time processes in the region associated with the digital controller as the controller of the control elements that control systems and computing discrete time. Depending on requirements, a digital controller can be shaped microcontroller and ASIC to a standard desktop computer. Because the digital computer system is discrete, then the Laplace transform is used in the control system is replaced with the Z-transform. Therefore, you must understand about the concept of continuous time and discrete time concept.


Flow Chart - Digital Control system applications

Digital computer also has a limited precision (See quantization) extra care needed to ensure that errors in the coefficients, A / D conversion, D / A conversion, etc. do not produce unwanted effects or planned.

The application of digital control can easily be done when used in a feedback form. Since the creation of the first digital computer in the early 1940s the price of digital computers has dropped significantly. The reason this is one of the many reasons for the application of digital control systems for the control of the control system. Other reasons:

Flexibile: easy to configure and reconfigure through software
* Scalable: can be set up programs tailored to the limits of memory or storage space at no extra cost
* Adaptable: program parameters can be changed with the times
* Static operation: digital computers are much more susceptible to environmental conditions rather than of capacitors and inductors
ReadMore..

Friday, October 17, 2014

Digital Step Km Counter Circuit Diagram

This circuit measures the distance covered during a walk. Hardware is located in a small box slipped in pants pocket and the display is conceived in the following manner: the leftmost display D2 (the most significant digit) shows 0 to 9 Km. and its dot is always on to separate Km. from hm. The rightmost display D1 (the least significant digit) shows hundreds meters and its dot illuminates after every 50 meters of walking. A beeper (excludable), signals each count unit, occurring every two steps. A normal step was calculated to span around 78 centimeters, thus the LED signaling 50 meters illuminates after 64 steps (or 32 operations of the mercury switch), the display indicates 100 meters after 128 steps and so on.

For low battery consumption the display illuminates only on request, pushing on P2. Accidental reset of the counters is avoided because to reset the circuit both pushbuttons must be operated together. Obviously, this is not a precision meter, but its approximation degree was found good for this kind of device. In any case, the most critical thing to do is the correct placement of the mercury switch inside of the box and the setting of its sloping degree.

Digital Step-Km Counter  Circuit diagram:


digital_step_km_counter_circuit_diagram
Digital Step-Km Counter Circuit Diagram



Parts:
R1 = 22K 1/4W Resistor
R2 = 2.2M 1/4W Resistor
R3 = 22K 1/4W Resistor
R4 = 1M 1/4W Resistor
R5 = 4.7K 1/4W Resistor
R6 = 47R 1/4W Resistor
R7 = 4.7K 1/4W Resistor
R8 = 4.7K 1/4W Resistor
R9 = 1K 1/4W Resistor
C1 = 47nF 63V Polyester Capacitor
C2 = 100nF 63V Polyester Capacitor
C3 = 10nF 63V Polyester Capacitor
C4 = 10µF 25V Electrolytic Capacitor
D1 = Common-cathode 7-segment LED mini-display (Hundreds meters)
D2 = Common-cathode 7-segment LED mini-display (Kilometers)
Q1 = BC327 45V 800mA PNP Transistors
Q2 = BC327 45V 800mA PNP Transistors
P1 = SPST Pushbutton (Reset)
P2 = SPST Pushbutton (Display)
IC1 = 4093 Quad 2 input Schmitt NAND Gate IC
IC2 = 4024 7 stage ripple counter IC
IC3 = 4026 Decade counter with decoded 7-segment display outputs IC
IC4 = 4026 Decade counter with decoded 7-segment display outputs IC
SW1 = SPST Mercury Switch, called also Tilt Switch
SW2 = SPST Slider Switch (Sound on-off)
SW3 = SPST Slider Switch (Power on-off)
BZ = Piezo sounder
B1 = 3V Battery (2 AA 1.5V Cells in series)

Circuit operation:

IC 1A & IC 1B form a monostable multi vibrator providing some degree of freedom from excessive bouncing of the mercury switch. Therefore a clean square pulse enters IC2 that divides by 64. Q2 drives the LED dot-segment of D1 every 32 pulses counted by IC2. Either IC3 & IC4 divide by 10 and drive the displays. P1 resets the counters and P2 enables the displays. IC1C generates an audio frequency square wave that is enabled for a short time at each monostable count. Q1 drives the piezo sounder and SW2 allows disabling the beep.

Notes:
  • Experiment with placement and sloping degree of mercury switch inside the box: this is very critical.
  • Try to obtain a pulse every two walking steps. Listening to the beeper is extremely useful during setup.
  • Trim R6 value to change beeper sound power.
  • Push P1 and P2 to reset.
  • This circuit is primarily intended for walking purposes. For jogging, further great care must be used with mercury switch placement to avoid undesired counts.
  • When the display is disabled current consumption is negligible, therefore SW3 can be omitted.
ReadMore..

Thursday, September 18, 2014

Build a Digital Theremin Wiring diagram Schematic

Theremin schema shown in this schematic diagram uses digital component, so we can call it a digital Theremin. This schema employs  logic inverter 74C04 or CD4069 hex inverter and CD4046 phase-locked-loop (PLL) IC. 

The CD4069 logic inverter is operated as a fixed-frequency oscillator with  frequency around 100kHz. The CD4046 is operated as a variable frequency oscillator which is adjustable around 100kHz. The exact center frequency of the on-chip oscillator is determined by R4, C2 and R3. Here is the schematic diagram of the schema. 

Digital Theremin Circuit Diagram


The frequency of variable oscillator frequency schema can be shifted several kilohertz by moving your hand approaching the antenna since the C2 and the antenna form an equivalent parallel capacitance. The frequency of the variable oscillator should be set to the same frequency of fixed oscillator when there is no hand or human body close to the antenna. 

This  calibration is done by adjusting the  zero control R4 pot with this simple rule: If  both oscillators (the fixed and the variable) are set to the same frequency then the Theremin will produce no output (silent). This Theremin schema will start  producing audible tone if you move your hand approaching the antenna since it will shift the frequency of the variable oscillator. You can play this Theremin schema by moving your right hand around the antenna and at the same time turning the volume knob R5 with your left hand.
ReadMore..

Sunday, September 14, 2014

Digital Thermometer with data processing of a microcontroller AT89C4051

digital
Digital Thermometer 0-100.0°C is a digital thermometer that operates in modetemperature measurement in Celsius (° C). Digital Thermometer 0-100.0 ° C in this article uses data processor in the form of a microcontroller AT89C4051.



Temperature sensors used in Digital Thermometer 0-100.0 ° C. This temperature sensor LM35D. Digital Thermometer 0-100.0 ° C. It uses the temperature measurement data viewer in the form of 1 line LCD viewer. Digital Thermometer 0-100.0 ° C. It can display the temperature measurement data with a resolution of 0.1 ° C.

Digital
Digital Thermometer Circuit Diagram


Digital Thermometer 0-100.0 ° C. These temperature sensors make use of LM35D as temperature sensing. In Digital Thermometer 0-100.0 ° C. This temperature sensor measurement data this LM35D (Level Voltage) is then converted into 4-bit binary data using the ADC CA3162.

Then the 4-bit data from ADC CA3162 which is a measurement of data if the temperature is in the AT89C4951 microcontroller so that it becomes an operating principle of temperature measurement based on digital thermometers. In the final stage of the Digital Thermometer 0-100.0 ° C. This is the appearance of digital data temperature measurement, using digital data viewer of the LCD 1 line.
ReadMore..

Monday, August 18, 2014

Digital Bike Tachometer SP

This digital SP tachometer for bikes uses 2 reed switches to urge the speed data of the bicycle. The reed switches are put in close to the rim of the wheel where permanent magnets pass by. The permanent magnets are connected to the wheelspokes and activate the reed switches everytime they pass by it. The speed is digitally displayed.

The tachometer schema works in step with this principle; the pulses created by the reed contacts are counted inside an explicit time interval. The ensuing count is then displayed and represents the speed of the bike. 2 4026 ICs are used to count the pulses, decode the counter and management 2 7-segment LED show. RS flip-flops U3 and U4 perform as anti-bounce.

Electronic bicycle SP tachometer schema diagram



The pulses arrive at the counter’s input through gate U7. The measuring amount is set by monostable multivibrator U5/U6 and might be adjusted through potentiometer P1 so the tacho are often calibrated. The schema U1/U2 resets the counters.

Since batteries are used to power the schema, its not sensible to support the continual show of speed data. This schema isnt continuously active. The schema is activated solely once a button is pressed. a minimum of 3 permanent magnets should be put in on the wheel. The schema are often calibrated with the assistance of another pre-calibrated tachometer.


Author: alen mark Sourced by: diagramstream