Showing posts with label meter. Show all posts
Showing posts with label meter. Show all posts

Saturday, October 25, 2014

PIC16F873 Ultrasonic Range Meter Diagram Circuit


This circuit is measuring the range to an object by using ultrasonic transmitter and ultrasonic receiver. The distance is calculated by PIC microprocessor and is displayed on the three digit 7-segment LED display.

Source:http://www.hobby-elec.org/e_pic6_6.htm
Thank you.
ReadMore..

Thursday, October 23, 2014

Volt meters ampere meter with PIC

Volt meters & ampere meter with PIC can be used to measure voltage and current simultaneously. The series of volt meters & ampere meter with PIC16F876A PIC is used as a data processor voltage and current are measured. 

This circuit uses the viewer in the form of 16 × 2 LCD used for the data menmpilkan voltage and current measurements. In the article volt meter and ampere meter with PIC are discussed kerannya limited to devices only. More detail can be seen from the image sequence volt meter and ampere meter with PIC below. 

The images of Volt Meter & Ampere Meter With PIC Circuit

Volt meters & ampere meter with PIC 
ReadMore..

Measure your stress level – Tension meter

If you, like so many other people in this day and age, arrive home from work stressed out and with the problems of the day still lingering,this simple little instrument will go a long way to relieving nervous tension.
Of the various types of feedback devices, probably the best approach for the amateur experimenter is the Galvanograph, better known as the Galvanic Skin Response Monitor. The instrument described here relies for its operation on changes in skin resistance in sympathy with changes in emotional state. An increase in tension level reduces skin resistance and, conversely, a decrease in tension is accompanied by an increase in skin resistance.
The correlation between emotional stress and skin resistance is still not fully understood. What is known, though, is that minute changes in the permeability of the skin produce corresponding voltage variations across two electrode pads attached to two fingers on the same hand.

Measure


Tension Monitor meter circuit

These signal fluctuations are amplified and fed to an oscillator to produce an audible tone. A decrease in pitch therefore signifies a decrease in tension, and vice-versa. A visual indicator in the form of a panel meter also aids the user in monitoring tension levels. The monitor is quite sensitive to fluctuations. During use, a sudden moment of stress, even a deep sigh, will increase the pitch and cause a shift of the meter needle. Circuit Details In the circuit diagram of Fig.1, IC1 is configured as an astable multivibrator to drive an 8-ohm miniature speaker LS1 via capacitor C3, resistor R6 and volume control potentiometer VR2. The latter allows users to set a desired level and avoid it becoming a distraction.
Whereas the trigger input of IC1 is normally connected to the positive rail via a resistor in a conventional 555 oscillator, here it is connected via resistor R4 to the emitter of transistor TR1. The base of TR1 is connected between one electrode pad and the voltage divider formed by potentiometer VR1 and resistor R1. It will be seen that with the pads fitted to the fingers, the tone level will be dependent on the setting of VR1 and skin resistance. Resistor R2 in the transistor base is necessary should the pads be accidentally touched together. A 1mA meter is fitted in the collector line, along with R3, as a visual indicator. Although not essential or intended to measure current levels, it does help to emphasize fluctuations in emotional level.
The design of the pads is not critical. For the prototype, stripboard was used. The tracks were wired together at one end and connected to a 30cm length of twin lighting flex. The pads were then glued to Velcro straps. When the unit is first switched on, a highpitched tone should be heard, rapidly diminishing and ceasing. Turn the Sensitivity control VR1 to the minimum setting. Attach the electrodes to the fleshy pads of the first two fingers on the less-dominant hand with the Velcro straps, firmly but not tight. Rest the hand comfortably and keep it reasonably still, allowing half a minute for the pads to “bond”. Normally, at the minimum setting, the oscillator will hardly tick over, unless the user is in a high state of anxiety. Keep in mind that any form of stimulant, and that includes tea, coffee, alcohol and cigarettes, will reduce one’s capacity to relax. Rotate the control until a medium pitched tone is obtained and apply your relaxation technique. The monitor does not teach any method of meditation or relaxation; it only monitors the effectiveness of the technique applied. The tone should slowly diminish, with fluctuations as unconscious thoughts flit across the mind.When the sound ceases altogether, repeat the above procedure by increasing VR1. Twenty minutes is considered by therapists to be an adequate relaxation session.
ReadMore..

Monday, September 8, 2014

Build a LF or HF field Strength Meter Wiring diagram Schematic

How to Build a LF or HF field Strength Meter Circuit Diagram ? That is a good question but i share with you friend short description may be you are very genius you can make it easily . In this schema CI and LI resonate on the 1750 meter band, with coverage from 150 kHz to 500 kHz. LI can be slug-tuned for 160-to-190 kHz coverage alone or a 2.5 mH choke can be used for LI, if desired, using CI for tuning. A 1N270 germanium diode rectifies the RF signal and C2 is charged at the peak RF level. 

 LF or HF field Strength Meter Circuit Diagram


LF

This dc level is amplified by an LM358. The gain is determined by R2 and R3, 1 100-kilohm linear potentiometer that varies the dc gain from 1 to 100, driving the 50 microampere meter. This field strength meter need not be limited to LF use. The Table shows the LI and CI values for HF operation and broadband operation.
ReadMore..

Thursday, August 21, 2014

Field strength meter

This schema, enclosed in a small plastic box, can be placed into a bag or handbag. A small magnet is placed close to the reed switch and connected to the hand or the clothes of the person carrying the bag by means of a tiny cord.
If the bag is snatched abruptly, the magnet looses its contact with the reed switch, SW1 opens, the schema starts oscillating and the loudspeaker emits a loud alarm sound.
The device can be reverse connected, i.e. the box can be placed in a pocket and the cord connected to the bag.
This device can be very useful in signalling the opening of a door or window: place the box on the frame and the magnet on the movable part in a way that magnet and reed switch are very close when the door or window is closed.

















Parts:
R1 330K 1/4W Resistor
R2 100R 1/4W Resistor
C1 10nF 63V Polyester or Ceramic Capacitor
C2 100µF 25V Electrolytic Capacitor
Q1 BC547 45V 100mA NPN Transistor
Q2 BC327 45V 800mA PNP Transistor
SW1 Reed Switch and small magnet (See Notes)
SPKR 8 Ohm Loudspeaker (See Notes)
B1 3V Battery (two A or AA cells wired in series etc.)

Notes:

The loudspeaker can be any type, its dimensions are limited only by the box that will contain it.
An on-off switch is unnecessary because the stand-by current drawing is less than 20µA.
Current consumption when the alarm is sounding is about 100mA.
If the schema is used as anti-bag-snatching, SW1 can be replaced by a 3.5mm mono Jack socket and the magnet by a 3.5mm. mono Jack plug with its internal leads shorted. The Jack plug will be connected with the tiny cord etc.
Do not supply this schema with voltages exceeding 4.5V: it will not work and Q2 could be damaged. In any case a 3V supply is the best compromise.

ReadMore..