Showing posts with label switch. Show all posts
Showing posts with label switch. Show all posts

Tuesday, November 18, 2014

Triac Light Switch as a dimers

The series of light switches this time slightly different from the voltage of work. The series of light switches can work directly on the AC power network. Light switches are using the main component of TRIAC and LDR. The circuit is very simple and the components were sold in the market.

If you want a light reception sensitivity of this circuit can be arranged then the 3.3 MOhm resistor can be replaced with a variable resistor. For more details can be seen from the following series of images.
Triac Light Switch as a dimers Circuit Diagram

With Triac Light Switch series is as dimers, but dimers control performed by the reception of light around the LDR. The lower the intensity cayaha received LDR then  bright lights. For installation LDR need to be considered so as not exposed to light from the lamp directly.
ReadMore..

Wednesday, October 29, 2014

Automatic AC Power Switch Circuit Diagram

Holiday Home Electrical appliances accidentally left on  in (holiday) homes left unoccupied for a  short or a long period consume power  unnecessarily and can present a fire hazard. Everyone will be familiar with those  nagging thoughts, a few miles down the  road from the house: “Did I remember  to switch off the coffee machine? The  lights? The oven?” 

Automatic AC Power Switch Circuit diagram :

Automatic
Automatic AC Power Switch Circuit Diagram

Hotel rooms are often equipped with a  switch near the main door which enables the power supply to everything in  the room only when the plastic card (which  might contain a chip or have a magnetic strip  or a pattern of holes) that serves as the room  key is inserted. The circuit idea given here  to switch off lights and other appliances is  along the same lines. The solution is surprisingly simple. 

A reed contact is fitted to the frame of the main entrance door, and a matching magnet  is attached to the door itself such that when  the door is closed the reed contact is also  closed. To enable power to the house, press  S1 briefly. Relay RE1 will pull in and complete  the circuit for all the AC powered appliances in  the house. The relay will be held in even after  the button is released via the second relay contact and the reed contact (‘latching’ function). 

As soon as the main entrance door is  opened, the reed contact will also open.  This in turn releases the latch circuit and  consequently the relay drops out. The  various connected appliances will thus  automatically and inevitably be switched  off as soon as the house is left. The circuit is principally designed for  small holiday homes, where this mode  of operation is particularly practical. Of course, for any circuit that deals in AC  powerline voltages, we must mention  the following caution. 

Caution:
shock hazard! Construction and connection of this circuit  should only be carried out by suitably-qualified  personnel, and all applicable electrical safety  regulations must be observed. In particular, it  is essential to ensure that the relay chosen is  appropriate for use at domestic AC grid volt-ages and is suitably rated to carry the required  current.
ReadMore..

Tuesday, October 28, 2014

Temperature Sensitive Switch For Solar Collector Diagram Circuit

This circuit can be used to turn the pump on and off when a solar collector is used to heat a swimming pool, for example. This way the water in the collector has a chance to warm up significantly before it is pumped to the swimming pool. A bonus is that the pump doesn’t need to be on continuously. The basis of operation is as follows. When the temperature of the water in the solar collector is at least 10 °C higher than that of the swimming pool, the pump starts up.

The warm water will then be pumped to the swimming pool and the temperature difference will drop rapidly. This is because fresh, cool water from the swimming pool enters the collector. Once the difference is less than 3 °C the pump is turned off again. R10/R1 and R9/R2 each make up a potential divider. The output voltage will be about half the supply voltage at a temperature around 25 °C. C7 and C8 suppress any possible interference.

The NTCs (R9 and R10) are usually connected via several meters of cable, which can easily pick up interference. Both potential dividers are followed by a buffer stage (IC1a/IC1b). IC1c and R3, R4, R5 and R6 make up a differential amplifier (with unit gain), which measures the temperature difference (i.e. voltage difference). When both temperatures are equal the output is 0 V. When the temperature of the solar collector rises, the differential amplifier outputs a positive voltage.

This signal is used to trigger a comparator, which is built round an LM393 (IC2a). R7 and P1 are used to set the reference voltage at which the comparator changes state. R8 and P2 provide an adjustable hysteresis. R11 has been added to the output of IC2a because the opamp has an open collector output. A power switch for the pump is created by R12, T1 and Re1. D1 protects T1 against voltage spikes from the relay coil when it is turned off.

A visual indication of the state of the controller is provided by IC4 (UAA170), a LED spot display driver with 16 LEDs. The reference voltage for the comparator is buffered by IC1d and fed to input VRMAX of the UAA170. R20/D21 and R23/D22 limit the input voltages of IC4 to 5.1 V, since the maximum permissible input voltage to the UAA170 is 6 V. When there is no temperature difference, LED D20 turns on.

Circuit diagram:
Temperature Sensitive Switch Circuit Diagram For Solar Collector

As the temperature difference increases the next LED turns on. The full scale of the LED bar is equal to the reference voltage of the comparator. This means that when the last LED (D5) of the UAA170 turns on, the comparator switches state. This is also indicated by D2. The power supply has been kept fairly simple and is built around a LM7812 regulator. The circuit is protected against a reverse polarity at the input by D3.

You have to make sure that the input to the regulator is at least 15 V, otherwise it won’t function properly. There are a few points you should note regarding the mounting of the NTCs. NTC R9 should be placed near the output of the solar collector. You should choose a point that always contains water, even when some of the water flows back a little. NTC R10 should be mounted inside the filter compartment (where it exists), which continually pumps the swimming pool water.

This will give a good indication of the temperature of the water. The way the circuit has to be set up depends how it has been installed and is very much an experimental process. To start with, set hysteresis potentiometer (P2) halfway. Then set the reference voltage to about 1.5-2 V with P1. On a sunny day you can measure the voltage difference to get an idea as to which reference voltage needs to be adjusted. The hysteresis setting determines how long the pump stays on for, which is until the minimum temperature difference has been reached.
Author: Tom Henskens - Copyright: Elektor Electronics Magazine
ReadMore..

Sunday, October 5, 2014

Latest Light Sensitive Switch with LDR 2N2926

This be circuit warn when be become dark, or Light sensitive switch. By use electronics part the base is important , be the transistor 2N2926 and AC128. For the light sensor also LDR (light dependent resistor) or a resister quickly the light. When have no the light makes Q1 , stop work. The Q2 and Q3 then work, It then send current give buzzer utter loud immediately. By circuit arrangement of Q1,Q2 be the character of Schmitt trigger help testify modify analog signal to digital 2 the level well. And help decrease the condition disturbs all with. The detail is other , see in the circuit.

 

ReadMore..

Monday, September 15, 2014

220V Light Operated On Off Switch

220V

This schematic diagram is a light-operated, remote-controlled solidstate switch schema to handle lamp. While in darkness, the resistance of Light Dependent Resistor (LDR) is extremely hight, it shoots up to megohm range. As a result, the triac isnt going to have gate drive and therefore it doesnt conduct.

When LDR is lighted by way of a torch-light beam, the level of resistance of LDR immediately reduces (under 10Kohm). This leads the triac to conduct and turn on the lamp. Light received from your lamp (normal lamp in the room, not from the torch) will keep LDR’s resistance low. So, the lamp stays continually "on". When the lamp is ‘on’, it could be turned "off’ once again by disturbing the light falling on LDR, by either waving hand in front of it or by disturbing power source for the schema for just a moment.

RFC applied right here could be built by winding about 15 turns of 18 SWG wire over an insulated ferrite rod.
Circuit title: 220V Light-Operated On/Off Switch. This kind of schema also can be modified to make a alarm schema for security purpose.
ReadMore..

Wednesday, September 10, 2014

Audio Controlled Mains Switch

Audio Controlled Mains Switch Circuit diagram. It is often useful for audio or video equipment to be switched off automatically after there has been no input signal for a while. The function of the on-off switch in such equipment is then taken over by switch S2 in the accompanying diagram. It remains, however, possible to  switch off manually by means of Si. Automatic  switch-off occurs after there has been no input  signal for about 2 minutes: this delay makes it possible for a new record or cassette to be placed in the  relevant machine.
 
The audio input to the proposed schema may be  taken from the output of the relevant TV set, amplifier, or whatever. The input earth is held at + 6 V  with respect to the schema earth by potential divider  Ri-R2-R3-R4. The two 741s function as comparators: the output of ICi goes high when the in- put signal is greater than + 50 mV, whereas the out- put of IC2 goes high when the input signal  becomes more negative than -50 mV. Resistors  R6, R7, and R8 form an OR gate that drives transistor Ti. If the output of either ICi or IC2 is logic  1, Ti conducts.
 
Audio Controlled Mains Switch Circuit diagram :

Audio
 
Audio Controlled Mains Switch Circuit Diagram

The 555  operates as a retrigger able monostable,  whose period is determined by Rio and Ci. The  device is triggered when its pin 2 is earthed by the  closing of S2. Its output, pin 3, then remains high  for 1 to 2 minutes, depending on the leakage cur- rent of the 555. 

The monostable resets itself as soon  as the potential across Ci exceeds a certain value.  As long as there is an input signal to the schema, Ti conducts and Ci remains uncharged. As soon as  the audio signal ceases, Ti switches off, and Ci  charges until the potential across it is sufficient to  reset the 555. The monostable may also be reset by  closing Si, which connects pin 6 of the 555 to + 12 V.
 
Audio-Controlled-Mains-Switch
When IC3 is reset, Ci is discharged via its pin 7. Resistor Rrn serves as protection, because without it Ti could short-schema the supply lines. When the output of IC3 goes high, T2 conducts,  the relay is energized, and the relay contacts switch on the mains voltage as appropriate. To counter the induced potential when the relay contacts close, which could damage T2, diode Di has been connected in parallel with the relay coil. 

ReadMore..

Doorbell Warning Switch

This schema will light a lamp at a remote location when the doorbell switch is pressed. This schema should only be used with the solenoid type doorbells, the electronic type that play tunes will not work here.  It is quite easy to miss the sound of a doorbell if you are watching TV , this schema gets round the problem by providing a visual indication. As an alternative, a LED could also be used. You could just parallel a lamp across the doorbell, but this would mean extra drain from the doorbell batteries or transformer.


Circuit
A series resistor, R1 is wired in series with the doorbell and reduces current flow, thereby increasing battery life. The value of R1 is chosen so that about 0.6 to 0.7 volts is developed across it, when the doorbell switch is pressed. I used a combination of a 22 ohm resistor in parallel with a 50 ohm. The voltage drop across R1 is sufficient to switch on the transistor, the lamp in series with the collector will then illuminate. I also used an electromechanical counter in parallel with the lamp.
ReadMore..

Sunday, September 7, 2014

Alarm Voiecer For Bend Switch Wiring diagram Schematic

This is a Alarm Voiecer For Bend Switch Circuit Diagram. This is a cross-sectional diagram of a bend switch. They can be used as push button or even position sensors. This schematic diagram shows an oscillator, which is used as an alarm voiecer, triggered by a bend switch. Read: Simple Power On Reset Circuit Diagram

Alarm Voiecer For Bend Switch Circuit Diagram

Alarm


ReadMore..

Wednesday, September 3, 2014

Video Switch for Intercom System

Video Switch for Intercom System. Nowadays a lot of intercom units are  equipped with video cameras so that you can  see as well as hear who is at the door. Unfortunately, the camera lens is perfectly placed  to serve as a sort of support point for people  during the conversation, with the result that  there’s hardly anything left see in the video  imagery.  One way to solve this problem is to install two cameras on the street side instead only  one, preferably some distance apart. If you  display the imagery from the two cameras  alternately, then at least half of the time you  will be able to see what is happening in front  of the door. Thanks to the video switch module described  here, which should be installed on the street  side not too far away from the two cameras,  you need only one monitor inside the house and you don’t need to install any additional video cables.
 
Circuit diagram :
Video
Video Switch for Intercom System Circuit Diagram

Along with a video switch, the schema includes  a video amplifier that has been used with  good results in many other Elektor projects,  which allows the brightness and the contrast  to be adjusted separately. This amplifier is  included because the distance between the  street and the house may be rather large, so it is helpful to be able to compensate for cable attenuation in this manner.  The switch stage is built around the well  known 4060 IC, in which switches IC2a and  IC2d alternately pass one of the two signals to  the output. They are driven by switches IC2b and IC2c, which generate control signals that  are 180 degrees out of phase. The switching rate for the video signals is  determined by a clock signal from an ‘old  standby’ 555 IC, which causes the signals to  swap every 2 seconds with the specified com ponent values.
 
Naturally, this schema can also used in many other situations, such as where two cameras are needed for surveillance but only one video cable is available.
 
Author :Jacob Gestman Geradts - Copyright : Elektor
ReadMore..

Saturday, August 23, 2014

Affordable Vhf Uhf Diode Rf Switch Wiring diagram Schematic

This is the very cheap low priced schema. This is an affordable Vhf/Uhf diode Rf switch schema diagram. This schema uses low-cost IN4148 diodes and exhibits about 1.5 dB insertion loss from 10 to 1000 MHz with a few volts of negative bias. D3 conducts and D1/D2 are cut off, which results in 30 to 50 dB isolation. When a few volts of positive bias are applied, Dl and D2 are biased on and D3 is cut off. This schema should be useful in applications where a low-cost RF switch is necessary.

Affordable Vhf-Uhf Diode Rf Switch Circuit Diagram


ReadMore..

Monday, August 18, 2014

Capacitor and Resistor in One Switch Box

It would be nice and comfortable doing our work and what we needed are readily available to save time and effort. It lessens the hassle of looking for missing pieces or even using multiple devices to check the accuracy and effectiveness of the equipments we are using.

pacitor
Just like this switch box that has a capacitor and resistor in one unit. It will be easier and faster to check the capacitance and resistance by switching the knobs. This device may look old-fashioned but can really come very handy. This is simple and not that expensive to make and very useful in electronic projects or for the purpose of collecting devices for future use.

pacitor




ReadMore..

Thursday, August 14, 2014

Switch Mode Power Supply Wiring diagram Schematic

The SMPS described here is suit-able for high-wattage stereos and other similar equipment. The schema employs two high-voltage power transistors (BU208D) which have built-in re-verse-connected di-odes across their collectors and emitters. It can supply about 250-watt out-put. The schema uses a ferrite core transformer of 14mm width, 20mm height, and 42mm length of E-E cores. An air gap of 0.5 mm is required between E-E junction. Good insulation using plastic-insulating sheets (Mylar) is to be maintained between each layer of winding.

 Switch Mode Power Supply Circuit Diagram

 Switch Mode Power Supply Circuit Diagram

The number of primary turns required is 90 with 26 SWG wire. The secondary winding employs 17 SWG wire (for 4A load current). Each turn of the secondary develops approximately 2 volts. The reader can decide about the output volt-age and the corresponding secondary turns, which would work out to be half the desired secondary voltage. The volt-age rating of capacitors C7 and C8 should be at least twice the secondary output of each secondary section. BY396 rectifier diodes shown on the secondary side can be used for a maximum load current of 3 amperes.

Two feedback windings (L1 and L2) using two turns each of 19 SWG wire are wound on the same core. These windings are connected to transistors T1 and T2 with a phase difference of 180o,  as shown by the polarity dots in the figure. First wind the primary winding (90 turns using 26 SWG wire) on the former. Then wind the two feedback windings over the secondary (output). Ensure that each winding is separated by an insulation layer.  Two separate heat sinks are to be pro-vided for the two transistors (BU208D).

The filter capacitor for mains should be of at least 47µF, 350V rating. It is better to use a 100µF, 350V capacitor. If the output is short-schemaed by less than 8-ohm load, the SMPS would automatically turn off because of the absence of base current.  The hfe min (current amplification factor) of BU208D is 2.5. Thus, sufficien base current is required for fully satu rated operation, otherwise the transistors get over-heated. At times, due to use of very high value of capacitors C7 and C8 (say 2200mF or so) on the secondary side or due to low load, the oscillations may cease on the primary side. This can be rectified by increasing the value of capacitor C6 to 0.01mF.

Author :  Deepu P.A
ReadMore..