Showing posts with label universal. Show all posts
Showing posts with label universal. Show all posts

Sunday, October 5, 2014

Universal DC DC Converter Circuit



Description:
This circuit will generate a smaller DC output voltage from a larger DC input voltage.It is quick and simple to make and by changing the value of the zener diode, the circuit can be universally adapted to provide other output voltages.The circuit and all diagrams represent a DC convertor with 12V battery input and 9Volt DC output.

The output voltage is equal to the zener diode voltage less 0.7 volts, or :-

Vo = Vz - 0.7 where V z is the value of the zener diode.

With the 10V zener diode as shown in the diagram the output voltage is about 9.3 Volts DC. The supply voltage used must always be at least a few volts higher than the zener voltage. In this example I have used a 12 Volt DC battery to provide the regulated 9 Volt DC output.


The above graph shows how the output is affected by input voltage variations. This was produced with a load current of 100mA and using a 10 volt rated zener diode. Note that the circuit falls sharply out of regulation when the input voltage falls to 11.5 volt, hence the requirement for an adequate supply voltage.

Temperature stability is very good as the above graph shows. The output voltage changes by 8.5mV for every 10 degree rise in temperature. This is less than 1 mV / degree.

Power Dissipation
With a DC-DC convertor, the most important consideration is power dissipation in the output device. Power dissipation is the product of the transistors emitter current and collector-emitter voltage. With this circuit the maximum power dissipation of the BD139 or maximum collector current cannot be exceeded, otherwise the transistor will be destroyed.
Example:
With a 12 Volt supply and a 9 Volt, 100 mA load the dissipation is as follows. Using a 10 volt zener the output voltage will be about 9.3 volts DC therefore:

VCE * IC = (12 - 9.3) * 100 mA = 2.7 Watts

This is well within the maximum limits of power dissipation and collector current, which for the BD139 are 8 watts and 1 amp respectively. If higher load currents are required then the following circuit may be used.

Output dissipation is calculated in the same way, the BD131 has a maximum power dissipation of 15 watts and collector current of 3 amps. The output voltage is approximately 1.4 volts less than the zener diode voltage and supply voltage must be higher than the input voltage by at least 3 volts.
ReadMore..

Wednesday, August 13, 2014

Universal Tester for 3 pin Devices

Most 3-terminal active components can be  tested statically using just an ohmmeter. But  when you have a lot of these devices to test,  the procedure soon becomes boring. That’s  where the idea came from to combine fast,  easy testing for these types of device into a  single instrument. 

The unit described here enables you to test  NPN and PNP bipolar transistors, N-or Pchannel FETs or MOSFETs, UJTs, triacs, and thyristors. Regardless of the type of device, the  tests are non-destructive. Universal connectors allow testing of all package types, including SMDs (up to a point). The unit lets you  change from one type of device to another in  a trice. It avoids using a multi-pole switch, as  they’re too expensive and hard to find. 
.
Circuit diagram :
Universal Tester for 3-pin Devices-Circuit Diagram
Universal Tester for 3-pin Devices Circuit Diagram
.
Here’s how to build a versatile instrument at  a ridiculously low cost. IC1 is a 4066 quad CMOS switch which will let us switch between bipolar transistors and FETs. LEDs D1–D4 tell us about the condition  of the test device, when we press the ‘Test’  button. The 4066 can only handle a few milliamps, not  enough for the other component types to be  tested, hence the reason for using relay RE1.  This 12 V relay offers two NO contacts. The  first applies power to the UJT test schema, the  second applies it to the triac and thyristor test  schema. 
.
Extensive testing has shown that the best way  to test UJT transistors is to do so dynamically,  with the help of a relaxation oscillator. Net-work R11/C1 sets the oscillator frequency to  around 2 Hz. On pin B1 of the UJT we find a  nice sawtooth, which is not of much interest  to us here. However, pin B2 gives good but  very short pulses. IC2, wired as a monostable,  lengthens these pulses so they can be clearly  seen via LED D5. 

The relay’s second pole is going to drive the  thyristor’ sortriac’s trigger pin. The value of  R18 is a good compromise with respect to the varying trigger currents for this type of  device. Resistor R17 is important, as the hold-ing current must be high enough for a triac;  250 mA is a good compromise. LED D6 tells  you if the device is in good condition or not;  but watch out, the test result must be con-firmed by briefly cutting the power in order  to reset the triac. 

On the web page for this article [1] you’ll find  the author’s CAD files (PCB layout and front  panel) along with some photos of his project.  On the prototype, the LEDs and the ‘Test’  button were wired onto the copper side of  the PCB. The six female connectors for the  devices being tested were salvaged, but there  are lots of models available on the market (the  pitch is standard). The test cable crocodile  clips must be as small as possible for testing  SMD devices.
ReadMore..