Showing posts with label unit. Show all posts
Showing posts with label unit. Show all posts

Saturday, September 13, 2014

Mobile Phone Multipower Unit Wiring diagram Schematic

Most of the mobile phone complaints are related to the power supply. This is mainly because of improper charging and use of non-recommended chargers and low-quality batteries. Depending upon the make and model, the charging time of mobile phones varies from 1 hour to 3 hours. The charging current is also different for different models. So it is better to use the charger specified by the company only.

Equipment for measuring the capacity or the backup time of a battery are not readily available in the market. But by measuring the charging and discharging currents, the approximate backup time of a battery can be found out. For example, charge a battery of 4.8V, 400mA rating for 1 minute and check whether it can discharge for 1 minute through a 400mA torch bulb.

If the battery is discharged fully, it would not get charged again through a normal charger. The battery would require an initial charge or  boosting.

Here’s a multipurpose schema (see Fig. 1) for battery boosting as well as normal cellphone battery charging. You can boost the battery at 400 mA for two minutes and then charge using a normal charger or this car charger. Other features of this schema are a variable regulated DC voltage output (0-12V), voltage display panel meter, provision to measure charging/discharging current, ammeter, and micro soldering iron.

The supply voltage for the whole unit is given by a 230V/18V, 2A transformer. This is rectified by a bridge rectifier (1N5408 x 4), filtered, and given to the ICs (IC1, IC2, and IC3) of regulator 7812. Another regulator IC (7805) gives regulated 5V to the voltage display panel meter. The center tapping of the transformer is connected to LM7805. The panel meter displays the variable output voltage (0-12V). It is a 3½-digit LED display module, which is readily available in the market.

Mobile Phone Multipower Unit Circuit Diagram

Mobile

Since pin 2 of IC1 (IC 7812) is grounded through a 2-kilo-ohm preset (VR1), it produces an output voltage of 13V (12V+voltage drop across the preset). You can increase the output of IC1 up to 18V by varying the preset.

The output voltage of IC1 is given to transistor T1 (S8050) through 1kilo-ohm potentiometer VR4 and 2.2-kilo-ohm resistor R1. Potentiometer VR4 acts as the boosting voltage controller. The function of 2.2 kilo-ohm resistor is to limit the boosting current. Transistor T1 acts as the pre-current amplifier.

Power transistor T2 (3055) works as the current amplifier, while 1-kilo-ohm resistor R2 acts as a current limiter to transistor T2. The emitter of T2 is connected to point C of a 12V, 200-ohm relay.

In normal condition, discharge switch S2 is opened and points ‘A’ and ‘a’ of the relay are closed to ‘C’ and ‘c’, respectively. Hence the boosting out terminals get a supply of 12V maximum. This voltage can be varied from 0 to 12V by using boosting voltage controller VR4. The mobile phone battery is boosted from this variable DC output. The boosting voltage is also given to the digital voltmeter or panel meter for display of the variable DC output.

A volume unit (VU) meter is used for measuring the charging and discharging current. It works from 0.1V to 1V (max.). Within this voltage range, it reads a load current of maximum 1 amp. The maximum current reading can be set with the help of 10-kilo-ohm preset VR5 connected to the VU meter.

The VU meter, boosting terminal, and car charger are connected to ground through 1-ohm, 5W resistor R4. So the VU meter displays the current taken while charging and discharging according to the voltage drop across this resistor.

When discharge switch S2 is switched on, relay RL energises and points ‘A’ and ‘a’ come in contact with points ‘B’ and ‘b’, respectively. Now if a battery is connected to the boosting terminals, it discharges through the discharge bulb and the V-U meter reads the discharging current.

On adjusting 2-kilo-ohm preset VR2, IC2 (IC 7812) gives an output of 16.5V. This voltage is given to transistor T3 (3055), which works as a current amplifier, through 1-kilo-ohm potentiometer VR3 and 1-kilo-ohm current-limiting resistor R3. Potentiometer VR3 works as the voltage control for micro-tip soldering iron. A standard micro-tip iron needs 16V DC maximum to heat up to 300°C. The micro iron current amplifier drives a micro iron of 1W to 25W.

Regulator IC3 (IC 7812) produces an output of 13V by making use of diodes D5 and D6 connected in series at pin 2 towards ground for dropping 1V. This output is given to power transistor T4 (3055), which works as a current amplifier. An output of 12.5V is obtained at the collector of T4, which is given to the car charger.

The car charger works on DC and it has an inbuilt voltage regulator and current limiter. The input of car charger varies from 4V to 12V. The outputs of different car chargers depend on the make and model. Each charger has its own connector for connection to the mobile phone. The charger holder given here can be used to connect any model of car charger for charging a mobile phone battery.

Normally, mobile phones have a voltage rating of 2.4V to 4.8V. Be careful while connecting a substitute power supply, as even a slight increase in the applied voltage can damage the phone.

Some phones go dead due to a shorted RF power amplifier. If a battery is connected to such a handset, it may suddenly get fully discharged and become dead.

Thus it is advantageous to verify the overall loading of the handset before connecting an external power supply or battery. For the purpose, you can use an ohmmeter. The battery terminal of the handset reads 5 to 50 ohms in one direction and 1 kilo-ohm to 150 kilo-ohms in the other direction. If a wide difference is noted, the schema is either open or shorted.


Sourced By: EFY : Author: Hamza Anjumukkil
The author is chairman and R&D head of Britco & Bridco Pvt Ltd
ReadMore..

Sunday, August 31, 2014

1992 audi 80 Lock and Alarm Control Unit Wiring Diagram


In term of automotive , there are main lock systems, the manual and automatic lock system. The 1992 audi 80-Lock and Alarm Control Unit consists of power windows module, central lock system sensor, trunk lid alarm switch, hood alarm switch, seat belt warning module, and alarm horn.

The following schematic illustrates the Audi lock and alarm unit wiring diagram. The sensor produces alarm when an invader approaches your . The central lock unit or front passenger to simultaneously lock or unlock all the doors by pressing the key switch.
ReadMore..

Sunday, August 24, 2014

Simple Electrification Unit

The Simple Electrification Unit schema is intended for carrying out harmless experiments with high-voltage pulses and functions in a similar way as an electrified fence generator. The p.r.f. (pulse repetition frequency) is determined by the time constant of network R1-C3 in the feedback loop of op amp IC1a: with values as specified, it is about 0.5 Hz. The stage following the op amp, IC1b, converts the rectangular signal into narrow pulses. Differentiating network R2-C4, in conjunction with the switching threshold of the Schmitt trigger inputs of IC1b, determines the pulse period, which here is about 1.5 ms. The output of IC1b is linked directly to the gate of thyristor THR1, so that this device is triggered by the pulses.

The requisite high voltage is generated with the aid of a small mains transformer, whose secondary winding is here used as the primary. This winding, in conjunction with C2, forms a resonant schema. Capacitor C3 is charged to the supply voltage (12 V) via R3.When a pulse output by IC1b triggers the thyristor, the capacitor is discharged via the secondary winding. The energy stored in the capacitor is, however, not lost, but is stored in the magnetic field produced by the transformer when current flows through it. When the capacitor is discharged, the current ceases, whereupon the magnetic field collapses. This induces a counter e.m.f. in the transformer winding which opposes the voltage earlier applied to the transformer.

Simple Electrification Unit Circuit diagram:


Simple
Simple Electrification Unit Circuit Diagram

This means that the direction of the current remains the same. However, capacitor C2 is now charged in the opposite sense, so that the potential across it is negative. When the magnetic field of the transformer has returned the stored energy to the capacitor, the direction of the current reverses, and the negatively charged capacitor is discharged via D1 and the secondary winding of the transformer. As soon as the capacitor begins to be discharged, there is no current through the thyristor, which therefore switches off. When C2 is discharged further, diode D1 is reverse-biased, so that the current loop to the transformer is broken, whereupon the capacitor is charged to 12 V again via R3. At the next pulse from IC1b, this process repeats itself.

Since the transformer after each discharge of the capacitor at its primary induces not only a primary, but also a secondary voltage, each triggering of the thyristor causes two closely spaced voltage pulses of opposite polarity. These induced voltages at the secondary, that is, the 230 V, winding, of the transformer are, owing to the higher turns ratio, much higher than those at the primary side and may reach several hundred volts. However, since the energy stored in capacitor C2 is relatively small (the current drain is only about 2 mA), the output voltage cannot harm man or animal. It is sufficient, however, to cause a clearly discernible muscle convulsion.

Author: P. Lay - Copyright: Elektor Electronics
ReadMore..